You are seeing this message because your Web browser does not support basic Web standards. Find out more about why this message is appearing and what you can do to make your experience on this site better.


ABOUT ARCHIVES
Advanced Search

Welcome   | My Account | E-mail Alerts | Access Rights | Sign In


  Vol. 50 No. 6, June 1993 TABLE OF CONTENTS
  Archives
  •  Online Features
  LETTERS TO THE EDITOR
 This Article
 •References
 •Full text PDF
 • Reply to article
 •Send to a friend
 • Save in My Folder
 •Save to citation manager
 •Permissions
 Citing Articles
 •Citing articles on Web of Science (6)
 •Contact me when this article is cited
 Related Content
 •Similar articles in this journal
 Social Bookmarking
  Add to CiteULike Add to Connotea Add to Del.icio.us Add to Digg Add to Reddit Add to Technorati Add to Twitter What's this?

The Effect of Repositioning Error on Serial Magnetic Resonance Imaging Scans-Reply

Ruggero Capra, MD; Nicoletta Marciano, MD
Department of Neurology

Roberto Gasparotti, MD
Department of Radiology University of Medicine, Brescia Piazza Spedali Civili 1 25123 Brescia, Italy

Arch Neurol. 1993;50(6):570-571.

Since this article does not have an abstract, we have provided the first 150 words of the full text PDF and any section headings.

In Reply.

—We would like to thank Goodkin for his very interesting comments concerning our recent article entitled "Gadolinium-Pentetic Acid Magnetic Resonance Imaging in Patients With Relapsing Remitting Multiple Sclerosis."1 He clearly demonstrated that in serial magnetic resonance imaging studies of patients with multiple sclerosis, repositioning errors can be responsible in the apparent development of new enhancing plaques and, in general, of an overestimation of the total number of plaques.

We agree with his observations and conclusions that even small repositioning errors could affect the overall evaluation of the brain disease activity, since the appearance, disappearance, enlargement, or reduction in size of a single lesion could be erroneously attributed to a biologic phenomenon rather than to a technical problem. In our study, head repositioning, made with the help of a laser light marker, was based on a direct confrontation of the current reference T1-weighted midline sagittal image, . . . [Full Text PDF of this Article]